Описание

  • In combination with evaluation units ESM-BA...
  • Cube-shaped version 88 x 25 mm
  • Connection cable
  • Cable type: PVC
Alignment of read head and actuator Operating diagram, design A CMS-R-AZA
  • Typ. switch-on distance
  • Typ. switch-off distance
Dimension drawing CMS-R-AZA... Dimension drawingCMS-R-AZA... Technical dataApprovals Mechanical values and environment
Design A
Material
Cable material PVC
Housing material Fiber glass reinforced PPS
Weight
Net 0,5 kg
Ambient temperature -20 ... 60 °C
Degree of protection IP67
Mechanical life 100 x 106
Installation orientation Any, pay attention to marking
Tightening torque 0,4 ... 0,5 Nm
Number of NO contacts 2 NO contacts with fuse, 100 mA each and 1 NO contact with LED
Connection Hard-wired encapsulated cable with cable end sleeves 0.25mm2
Cable length 10 m
Number of LED displays 1 LED contact status indication
Method of operation Magnetic, reed contact
Electrical connection ratings
Rated conditional short-circuit current 100 A
Fusing
Power supply / safety contacts, external contact protection Fuse 10 A gG
Switching voltage 24 ... 35 V DC
Contact status indication 24 ... 35 V DC
Switching current max.100 mA
Contact status indication max.20 mA
Switching characteristics Parallel
Switching voltage according to UL
According to UL Class 2 max.24 V AC/DC
Series resistance
LED contact status indication 1,5 k?
Switching frequency, electrical
At I_min = 10 mA max.5 Hz
At nominal current 8 A max.0,1 Hz
Switching delay from state change 26 ms
Other
In compliance with EN ISO 13849-1: 2015, EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015, EN ISO 14119: 2013, IEC 60947-5-3: 2013
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
B10D 20 x 106
In combination with Evaluation unit ESM-BA201, ESM-BA202, ESM-BA203, ESM-BA301, ESM-BA302, ESM-BA303, ESM-BA201P, ESM-BA301P and Actuator CMS-M-AIOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.20 mm
Contact status indication/ LED max.15 mm
Assured operating distance Sao
Contact status indication/ LED min.7 mm
With center offset m=0 min.9 mm
''