Описание

  • In combination with evaluation unit CMS-E-AR
  • Cube-shaped version 88 x 25 mm
  • Connection cable
  • Cable type: PVC
Alignment of read head and actuator Operating diagram, design A CMS-R-AXG
  • Typ. switch-on distance
  • Typ. switch-off distance
Dimension drawing CMS-R-AXF.../CMS-R-AXG... Dimension drawingCMS-R-AXF.../CMS-R-AXG... Technical dataApprovals Mechanical values and environment
Design A
Material
Cable material PVC
Housing material Fiber glass reinforced PPS
Weight
Net 0,17 kg
Ambient temperature -20 ... 60 °C
Degree of protection IP67
Resilience to vibration In acc. with EN 60947-5-2
Mechanical life 100 x 106
Installation orientation Any, pay attention to marking
Tightening torque 0,4 ... 0,5 Nm
Number of NO contacts 3 NO contact
Connection Hard-wired encapsulated cable with cable end sleeves 0.75 mm2
Cable length 3 m
Method of operation Magnetic, reed contact
Electrical connection ratings
Rated insulation voltage Ui 26,4 V DC
Rated impulse withstand voltage Uimp 1,5 kV
Switching voltage 24 V DC
Switching current 8 ... 500 mA
Degree of contamination (external, according to EN 60947-1) 2
Switching characteristics Parallel
Switching voltage according to UL
According to UL Class 2 max.24 V DC
Work area
Repeat accuracy R max.10 %
Other
In compliance with EN ISO 13849-1:2015, EN 50178:1997, EN 60204-1:2006/A1:2009, EN ISO 14119:2013, EN 61000-6-2:2005, EN 61000-6-3:2007/A1:2011, EN 60947-5-3:2013
''